Hello all,
Exchange 2010, EV10SP4CHF2.
Exchange-server has been rebuild, and according to the one who rebuild it, the powershell scripts (Throttling and permission) have been run succesfully.
Mailboxes were moved to DR-server, on which this erroneous mailbox was created. DAG were failed back to 'new' server when rebuild was completed and accepted.
Archiving etc runs fine. When enabling a new mailbox for archiving, I get event 3139 - An non-specific error has occurred whilst enabling archiving for the mailbox "removed" Error: The parameter is incorrect. (0x80070057)
I ran a trace on agentclientbroker, and see the error returning. I verified the GC is available and used. (GC: in the logfile is the one closest to the Exchange server).
A snip is attached.
When checking ADUC, I see as Exchange Home Server the DR server. I am thinking this is what is causing this issue, but I am not sure.
Someone seen and actioned this before?