Hello all,
EV10SP4CHF2. One one site I manage I have the below events when SFW kicks off with event 6854 - Partitions Collector run has started.. This is followed immediately by the following 3 alerts:
First Event - 13360 - An error was detected while accessing the Vault Database 'EVAMRNAVaultStore1' (Internal reference: {CADODataAccess::ExecuteSQLCommand} [.\ADODataAccess.cpp, lines {1317,1319,1335,1358}, built Jul 10 17:51:36 2013]):
Description:
[Microsoft][ODBC SQL Server Driver][SQL Server]The query processor could not start the necessary thread resources for parallel query execution.
SQL Command:
EVManageCollections
Seconf Event - 6796 - A COM exception has been raised.
<0x80040e14>
Internal reference
{CVaultStoreDB::EnumSparseCollections} [.\VaultStoreDB.cpp, lines {5138,5148,5151,5152,5153,5154,5155,5156,5157,5160}, built Jan 7 10:48:36 2014]
An exception is raised when a process encounters an unexpected fault.
Third Event - 6842 - A Collector encountered an error.
Reason: <0x80040e14>
PartitionEntryID: 1772058216651B344A1F905A90D8833091q10000AMRNAMAILARCHIVE
Method: CCollector::DeleteEmptyCollections
Whilst looking at the eventlog, it looks like event 6842 shows the affected partitions. Could this be indicating a corruption on the partition? In database?
Anyone has an idea what to check further?
Thanks.
Gertjan